hall_filament_width_sensor: Sync runout and width sensor states

Keeps the width sensor state in sync with the associated runout sensor and
normalizes the output when the width sensor is disabled.

When the width sensor was disabled the associated filament sensor remained
enabled but was no longer updated so would be 'stuck' in the last state it
was in before the width sensor was disabled.

The toggle switch and readings in the web interface could also be out of sync
with the actual sensor and filament states, misleading the user.

Now, when the width sensor is disabled:
- The filament sensor is disabled
- The reported filament state is 'present'
- The reported filament diameter is the nominal diameter

When the width sensor is enabled:
- The filament sensor is enabled
- The reported filament state is the derived state
- The reported filament diameter is the measured value

Finally, `min_diameter` is now used to determine the runout state rather than
a fixed value of `0.5`.

Signed-off-by: Ben Lye ben@lye.co.nz
This commit is contained in:
Ben Lye authored and KevinOConnor committed 2026-04-08 14:57:04 -04:00
1 parent 48446a5448
commit 3a0b834f3a
2 files changed
+17 -8

No files matched your search

+2 -1
View File
@@ -249,7 +249,8 @@ object:
[filament_switch_sensor](Status_Reference.md#filament_switch_sensor)
- `is_active`: Returns True if the sensor is currently active.
- `flow_compensation_enabled`: Returns True if flow compensation is enabled.
- `Diameter`: The last reading from the sensor in mm.
- `Diameter`: Returns the last width reading in mm if the sensor is active or
the nominal filament diameter if it is not.
- `Raw`: The last raw ADC reading from the sensor.
## heater
+15 -7
View File
@@ -94,6 +94,7 @@ class HallFilamentWidthSensor:
desc=self.cmd_DISABLE_FILAMENT_WIDTH_LOG_help)
self.runout_helper = filament_switch_sensor.RunoutHelper(config)
self.runout_helper.sensor_enabled = self.is_active
# Initialization
def handle_ready(self):
# Load printer objects
@@ -112,12 +113,15 @@ class HallFilamentWidthSensor:
# read sensor value
read_time, read_value = samples[-1]
self.lastFilamentWidthReading2 = round(read_value * 10000)
# calculate diameter
diameter_new = round((self.dia2 - self.dia1)/
(self.rawdia2-self.rawdia1)*
((self.lastFilamentWidthReading+self.lastFilamentWidthReading2)
-self.rawdia1)+self.dia1,2)
self.diameter=(5.0 * self.diameter + diameter_new)/6
if self.is_active:
# calculate diameter
diameter_new = round((self.dia2 - self.dia1)/
(self.rawdia2-self.rawdia1)*
((self.lastFilamentWidthReading+self.lastFilamentWidthReading2)
-self.rawdia1)+self.dia1,2)
self.diameter=(5.0 * self.diameter + diameter_new)/6
else:
self.diameter = self.nominal_filament_dia
def update_filament_array(self, last_epos):
# Fill array
@@ -150,7 +154,7 @@ class HallFilamentWidthSensor:
self.runout_helper.note_filament_present(eventtime,
self.runout_dia_min <= self.diameter <= self.runout_dia_max)
# Does filament exists
if self.diameter > 0.5:
if self.diameter > self.runout_dia_min:
if len(self.filament_array) > 0:
# Get first position in filament array
pending_position = self.filament_array[0][0]
@@ -224,6 +228,7 @@ class HallFilamentWidthSensor:
was_active = self.is_active
self.is_active = True
self.runout_helper.sensor_enabled = True
response = ("Filament width sensor: ON"
+ "\nFlow compensation: "
+ ("ON" if self.enable_flow_compensation else "OFF"))
@@ -239,11 +244,14 @@ class HallFilamentWidthSensor:
def cmd_M406(self, gcmd):
response = "Filament width sensor: OFF"
self.is_active = False
self.runout_helper.sensor_enabled = False
# Stop extrude factor update timer
self.reactor.update_timer(self.extrude_factor_update_timer,
self.reactor.NEVER)
# Clear filament array
self.filament_array = []
# Tell the filament sensor that there is filament present
self.runout_helper.note_filament_present(self.reactor.NOW, True)
# Set extrude multiplier to 100%
self.gcode.run_script_from_command("M221 S100")
gcmd.respond_info(response)