Now they no longer are separate processes but one merged one.
Port detection now will only test the two most common baudrates plus
any additionally configured ones if there is more than one port to test,
that way the additional overhead of having to cycle through both port
and baudrate should be greatly reduced.
As a consequence all avr_isp references have been finally removed.
Closes#3394
Current Jinja versions no longer allow modifying variables set outside
of for loops inside them. So something like:
{% set mark_active = True %}
{% for item in items %}
# do something
{% if mark_active %}
# do something more
{% set mark_active = False %}
{% endif %}
{% endfor %}
no longer works - mark_active will be reset on every iteration of the
loop to its initial value False. The fix is to use namespaces to
hold the modifiable values instead:
{% set ns = namespace(mark_active = True) %}
{% for item in items %}
# do something
{% if ns.mark_active %}
# do something more
{% set ns.mark_active = False %}
{% endif %}
{% endfor %}
See also #1697 and
https://jinja.palletsprojects.com/en/2.11.x/templates/#assignments
The Jinja dependency upgrade thus introduces a breaking change for
plugins as well. However, it was necessary for security reasons: older
versions have a bug that could allow template authors to break out of
the template sandbox. Not a huge risk in the context of OctoPrint
(plugins already have a lot more power than jinja would give them),
but still overdue to fix.
This reverts commit 73fbd15b
The change causes a full rescan for renaming on the uploads folder.
Unintended, needs to be looked at closer at a later date.
We didn't change any code between the last working build and the current
state since this is the master branch, so stop complaining. We'll
fix this in maintenance/1.4.1 in one way or the other.
Anything that's been closed for over a year definitely is outdated.
We really don't want people to play necromancer on ancient tickets,
it just causes support overhead (having to explain that code has
changed a ton since then and issue is likely a different one) or
user frustration (no reply).
If we can't load stuff from the backend, don't get stuck in "pip not
available" mode (which confuses people terribly) but instead show a
dedicated error.
We can't query the setting from the firmware, and we also can't reliably
track it through OctoPrint as it could be modified through GCODE
triggered through a file on the SD card and/or interactions with the
controller. Hence we now properly reflect that this value is write only
by emptying it 5s after focus loss (with a little opacity pulse to warn
about that) and immediately on sending.
That should hopefully make it a bit clearer that this value cannot be
trusted and will never reflect the firmware value unless query commands
or status reports are added for that in firmware.
Closes#3569 (though in a different way than intended by OP)