If the PollingObserver is used under Py2 on a directory that contains
utf8 file names, the default listdir implementation (scandir isn't
natively available under Py2) will generate unicode instead of str. Due
to an insufficent instance check in watchdog that will lead to a
misidentification of an entry as an DirEntry object instead of a str,
and the attempt to read the name property from that will cause an
AttributeError.
We monkey patch watchdog to use our bundled scandir backport where
needed instead of trying to fix the instance check, as that will perform
better anyhow.
Closes#3676
Apparently some machines out there are a bit flaky after boot and it can
take a bit for connectivity to work. As suggested by @fieldOfView in
https://community.octoprint.org/t//177/9
we thus check connectivity three times in a row if negative before
reporting it as negative.
If the comm layer starts sending state changes (e.g. to auto detect)
before the constructor returns, self._comm in the printer interface is
still None and thus states can't be decoded.
Probably part of #3653
We don't want to try to send our beforeDisconnect script if we aren't
properly connected, as that will severely delay Disconnect execution, so
we now limit that to operational states and thus allow a quick(er)
connection abort during auto detection or connection attempt.
Instead hold them back until the next slot.
Otherwise we might never get the final switch to Offline as after that
there are no current data upgrades anymore.
Otherwise we might spam our send queue leading to a bunch of lines
piling up inside it, making cancelling/pausing take longer and longer.
Potential fix for #3649
That way we can display a login dialog if we require a specific set of
permissions, which then also gets displayed if the user is logged in but
lacks them.
If the user is already logged in and has the requested permissions, an
immediate redirect to the redirect URI is triggered.
At /recovery/ there's now a (for now basic) recovery dialog that
currently allows the core functionality from the system command menu, so
shutting down and rebooting the system, restarting OctoPrint and
restarting OctoPrint in safe mode. The most important part here is the
ability to restart in safe mode, as that will allow to get OctoPrint
back into working order if an errant third party plugin or language
pack has made the standard UI non functional.
For that reason, no third party plugins are enabled or utilized on the
recovery dialog, even the theming hook is aggressively error resilient.
In order to still allow to authenticate the user (no one but ADMIN
should be allowed to use the recovery UI) the loginui plugin has been
merged into core as its own endpoint /login/ which coreui and recovery
can redirect to. This is a welcome change considering that the loginui
was absolutely necessary anyhow, and it being a plugin was merely a side
effect of backporting from forcelogin. This has now been cleaned up.
Hopefully the hardware out there should be up to it by now and combined
with the in-browser video reviews it would be a pity to still default
to mpeg2.