It's no longer installable from source under OctoPi 0.14 due to an
unpinned setup_requires dependency on setuptools_scm, and since we still
have to support that installation scenario that is a problem. Thankfully
it's only used in the plugin manager for parsing the notice date, and
we can just use datetime.strptime for that.
With the inclusion of the ForceLogin plugin that doesn't serve a real
purpose anymore in most cases, and it was only ever more of a rate
limiting feature than an actual security measure anyhow. Plus it lead to
a ton of false security alarms along the lines of "OMG UI_API_KEY IN THE
SOCKET HANDSHAKE, PWNED!!1!".
On stock installations, the behaviour will be unchanged since the
ForceLogin plugin prevents any kind of API access without authentication
that isn't the login request itself, including access to blueprint
plugin endpoints that do not specify that they are unprotected.
If a user decides to disable the ForceLogin plugin but keep access
control enabled, anonymous API access will now be possible without API
key or the need to fetch the current UI API Key from the server via the
websocket or the source code of the index page. This is a change
compared to earlier behaviour, but with a very limited impact as as
mentioned the UI API Key was so far also easily obtainable either via
the websocket or by parsing a fresh copy of the HTML page.
If the user decides to disable access control, there's no change
compared to previous behaviour.
Disabling the API - which was so far the only real use case for having
the UI API Key in the first place apart from basic rate limiting - has
also been removed. Allowing this only made things horribly complex as
the default frontend fully depends on the API's availability. Users
who do not wish third parties to have access to the API should
simply leave the ForceLogin plugin enabled.
Chamber temperatures reported via M105 will only be parsed if the
fw reports chamber capabilities (through Cap:CHAMBER_TEMPERATURE:1) or
the currently selected printer profile has a heated chamber configured.
This is to avoid incompatibility issues with firmware variants that
might already use the C parameter for something else (which might be the
case since we don't have a reliable well defined standard that people
need to adhere to...)
Chamber temperature commands M141 and M191 will only be allowed to be
sent if the selected printer profile has a heated chamber configured.
This mirrors the behaviour for the bed temperature commands M140 and
M190 and heated bed configuration.
Display of chamber data in the graph will only happen if the printer
profile has a heated chamber configured.
Implements one workflow behind #321
Instead of a boolean option to block sending of M0 *and* M1 and
hardcoding them and M25 to pause an ongoing print, we now have two lists
for blocked commands and pausing commands respectively.
Blocked by default: M0 and M1.
Pausing by default: M0, M1 and M25.
Implements #2970
-4 or --ipv4 will behave as if "--host 0.0.0.0" (or any other specific
v4 address) was supplied and only bind the server socket to v4. It will
be ignored if a v6 address is set to bind to.
-6 or --ipv6 will only bind the server socket to v6 instead of dual
stack on both v4 and v6. It will be ignored if a v4 address is set to
bind to.
Implements #2904
Improves performance of file manipulation, especially in cases with a
lot of files in the folder, without the added complexity of fully
decoupling metadata file serialization from general processing.
Better fix for #3057
Makes more sense than putting them into sys.modules as <identifier>,
which also can cause conflicts (e.g. in the case of octoprint.plugins
.logging which then suddenly gets found instead of the built-in crucial
logging module).