Introduce ok timeout to detect stalls in auto report scenarios
If a printer supports auto reporting the temperature but doesn't also support sending "wait" if the command buffer runs dry, it can happen that a lost "ok" never gets detected properly because no timeout is ever triggered (the printer is in fact sending data after all), but we should actually try to get comms running again. Introducing a custom ok timeout solves this. We reset this every time we see an "ok", "wait" or "busy", but if we run into it while printing we perform the same steps as if we hadn't received any data at all from the printer over the duration of the currently active communication timeout value (whether to choose "communication" or "communicationBusy" here depends on whether we also detected support of the busy protocol or not).
This commit is contained in:
1 parent
7d3d3408eb
commit
8732ec9756
1 file changed
+24
-3
@@ -375,6 +375,7 @@ class MachineCom(object):
|
||||
self._connection_closing = False
|
||||
|
||||
self._timeout = None
|
||||
self._ok_timeout = None
|
||||
self._timeout_intervals = dict()
|
||||
for key, value in settings().get(["serial", "timeout"], merged=True, asdict=True).items():
|
||||
try:
|
||||
@@ -1231,6 +1232,7 @@ class MachineCom(object):
|
||||
|
||||
#Start monitoring the serial port.
|
||||
self._timeout = get_new_timeout("communicationBusy" if self._busy_protocol_detected else "communication", self._timeout_intervals)
|
||||
self._ok_timeout = get_new_timeout("communicationBusy" if self._busy_protocol_detected else "communication", self._timeout_intervals)
|
||||
|
||||
startSeen = False
|
||||
supportRepetierTargetTemp = settings().getBoolean(["feature", "repetierTargetTemp"])
|
||||
@@ -1258,6 +1260,9 @@ class MachineCom(object):
|
||||
|
||||
##~~ busy protocol handling
|
||||
if line.startswith("echo:busy:") or line.startswith("busy:"):
|
||||
# reset the ok timeout, the regular comm timeout has already been reset
|
||||
self._ok_timeout = get_new_timeout("communicationBusy" if self._busy_protocol_detected else "communication", self._timeout_intervals)
|
||||
|
||||
# make sure the printer sends busy in a small enough interval to match our timeout
|
||||
if not self._busy_protocol_detected:
|
||||
self._log("Printer seems to support the busy protocol, adjusting timeouts and setting busy "
|
||||
@@ -1358,10 +1363,25 @@ class MachineCom(object):
|
||||
handled = True
|
||||
|
||||
# process timeouts
|
||||
elif line == "" and (not self._blockWhileDwelling or not self._dwelling_until or now > self._dwelling_until) and now > self._timeout:
|
||||
# timeout only considered handled if the printer is printing
|
||||
elif ((line == "" and now > self._timeout) or (self.isPrinting() and now > self._ok_timeout)) \
|
||||
and (not self._blockWhileDwelling or not self._dwelling_until or now > self._dwelling_until):
|
||||
# We have two timeout variants:
|
||||
#
|
||||
# Variant 1: No line at all received within the communication timeout. This can always happen.
|
||||
#
|
||||
# Variant 2: No ok received while printing within the communication timeout. This can happen if
|
||||
# temperatures are auto reported, because then we'll continue to receive data from the
|
||||
# firmware in fairly regular intervals, even if an ok got lost somewhere and the firmware
|
||||
# is running dry but not sending a wait.
|
||||
#
|
||||
# Both variants can only happen if we are not currently blocked by a dwelling command
|
||||
|
||||
self._handle_timeout()
|
||||
handled = self.isPrinting()
|
||||
self._ok_timeout = get_new_timeout("communicationBusy" if self._busy_protocol_detected else "communication", self._timeout_intervals)
|
||||
|
||||
# timeout only considered handled if the printer is printing and it was a comm timeout, not an ok
|
||||
# timeout
|
||||
handled = self.isPrinting() and line == ""
|
||||
|
||||
# we don't have to process the rest if the line has already been handled fully
|
||||
if handled and self._state not in (self.STATE_CONNECTING, self.STATE_DETECT_BAUDRATE):
|
||||
@@ -1681,6 +1701,7 @@ class MachineCom(object):
|
||||
self._log("Connection closed, closing down monitor")
|
||||
|
||||
def _handle_ok(self):
|
||||
self._ok_timeout = get_new_timeout("communicationBusy" if self._busy_protocol_detected else "communication", self._timeout_intervals)
|
||||
self._clear_to_send.set()
|
||||
|
||||
# reset long running commands, persisted current tools and heatup counters on ok
|
||||
|
||||
Reference in new issue
Block a user