diff --git a/config/sample-cartographer-v3.cfg b/config/sample-cartographer-v3.cfg index ee1a6fd41..a8b9508a0 100644 --- a/config/sample-cartographer-v3.cfg +++ b/config/sample-cartographer-v3.cfg @@ -50,3 +50,4 @@ frequency: 24000000 i2c_address: 42 i2c_mcu: carto i2c_bus: i2c1_PB6_PB7 +descend_z: 0.5 diff --git a/docs/Config_Changes.md b/docs/Config_Changes.md index d50a0f8e6..cf2e5d759 100644 --- a/docs/Config_Changes.md +++ b/docs/Config_Changes.md @@ -8,6 +8,10 @@ All dates in this document are approximate. ## Changes +20260318: The `[probe_eddy_current]` config option `z_offset` has been +renamed to `descend_z`. Using the old name is deprecated and it will +be removed in the near future. + 20260214: The `MANUAL_STEPPER` G-Code command `STOP_ON_ENDSTOP` parameter has changed. See the [MANUAL_STEPPER](G-Codes.md#manual_stepper) documentation for diff --git a/docs/Config_Reference.md b/docs/Config_Reference.md index 55638c55d..94b332296 100644 --- a/docs/Config_Reference.md +++ b/docs/Config_Reference.md @@ -2317,7 +2317,7 @@ sensor_type: ldc1612 #intb_pin: # MCU gpio pin connected to the ldc1612 sensor's INTB pin (if # available). The default is to not use the INTB pin. -#z_offset: +#descend_z: # The nominal distance (in mm) between the nozzle and bed that a # probing attempt should stop at. This parameter must be provided. #i2c_address: diff --git a/docs/Eddy_Probe.md b/docs/Eddy_Probe.md index aaf50b7ff..e3de7da02 100644 --- a/docs/Eddy_Probe.md +++ b/docs/Eddy_Probe.md @@ -11,7 +11,7 @@ for further details. Start by declaring a [probe_eddy_current config section](Config_Reference.md#probe_eddy_current) -in the printer.cfg file. It is recommended to set the `z_offset` to +in the printer.cfg file. It is recommended to set `descend_z` to 0.5mm. It is typical for the sensor to require an `x_offset` and `y_offset`. If these values are not known, one should estimate the values during initial calibration. @@ -42,11 +42,11 @@ tool completes it will output the sensor performance data: ``` probe_eddy_current: noise 0.000642mm, MAD_Hz=11.314 in 2525 queries Total frequency range: 45000.012 Hz -z_offset: 0.250 # noise 0.000200mm, MAD_Hz=11.000 -z_offset: 0.530 # noise 0.000300mm, MAD_Hz=12.000 -z_offset: 1.010 # noise 0.000400mm, MAD_Hz=14.000 -z_offset: 2.010 # noise 0.000600mm, MAD_Hz=12.000 -z_offset: 3.010 # noise 0.000700mm, MAD_Hz=9.000 +z: 0.250 # noise 0.000200mm, MAD_Hz=11.000 +z: 0.530 # noise 0.000300mm, MAD_Hz=12.000 +z: 1.010 # noise 0.000400mm, MAD_Hz=14.000 +z: 2.010 # noise 0.000600mm, MAD_Hz=12.000 +z: 3.010 # noise 0.000700mm, MAD_Hz=9.000 ``` issue a `SAVE_CONFIG` command to save the results to the printer.cfg and restart. @@ -167,7 +167,7 @@ calibration routine output: ``` probe_eddy_current: noise 0.000642mm, MAD_Hz=11.314 ... -z_offset: 1.010 # noise 0.000400mm, MAD_Hz=14.000 +z: 1.010 # noise 0.000400mm, MAD_Hz=14.000 ``` The estimation will be: ``` diff --git a/klippy/extras/probe_eddy_current.py b/klippy/extras/probe_eddy_current.py index 1e31f4c73..11e05698b 100644 --- a/klippy/extras/probe_eddy_current.py +++ b/klippy/extras/probe_eddy_current.py @@ -206,7 +206,7 @@ class EddyCalibration: for pos, _, mad_hz, mad_mm in filtered: if len(points) and points[0] <= pos: points.pop(0) - msg = "z_offset: %.3f # noise %.6fmm, MAD_Hz=%.3f\n" % ( + msg = "z: %.3f # noise %.6fmm, MAD_Hz=%.3f\n" % ( pos, mad_mm, mad_hz) gcode.respond_info(msg) return filtered @@ -399,6 +399,12 @@ class EddyDescend: self._probe_offsets = probe_offsets self._param_helper = param_helper self._trigger_analog = trigger_analog + if (config.get('z_offset', None, note_valid=False) is not None + and config.get('descend_z', None, note_valid=False) is None): + config.deprecate('z_offset') + self._descend_z = config.getfloat('z_offset', above=0.) + else: + self._descend_z = config.getfloat('descend_z', above=0.) self._z_min_position = probe.lookup_minimum_z(config) self._gather = None def _prep_trigger_analog(self): @@ -406,8 +412,7 @@ class EddyDescend: sos_filter.set_filter_design(None) sos_filter.set_offset_scale(0, 1.) self._trigger_analog.set_raw_range(0, MAX_VALID_RAW_VALUE) - z_offset = self._probe_offsets.get_offsets()[2] - trigger_freq = self._calibration.height_to_freq(z_offset) + trigger_freq = self._calibration.height_to_freq(self._descend_z) conv_freq = self._sensor_helper.convert_frequency(trigger_freq) self._trigger_analog.set_trigger('gt', conv_freq) # Probe session interface @@ -471,8 +476,7 @@ class EddyEndstopWrapper: def probe_finish(self, hmove): pass def get_position_endstop(self): - z_offset = self._eddy_descend._probe_offsets.get_offsets()[2] - return z_offset + return self._eddy_descend._descend_z # Probing helper for "tap" requests class EddyTap: @@ -661,6 +665,14 @@ class EddyScanningProbe: self._gather.finish() self._gather = None +# Eddy specific ProbeOffsets class (does not store z_offset) +class EddyProbeOffsets: + def __init__(self, config): + self.x_offset = config.getfloat('x_offset', 0.) + self.y_offset = config.getfloat('y_offset', 0.) + def get_offsets(self, gcmd=None): + return self.x_offset, self.y_offset, 0. + # Main "printer object" class PrinterEddyProbe: def __init__(self, config): @@ -674,7 +686,7 @@ class PrinterEddyProbe: trig_analog = trigger_analog.MCU_trigger_analog(self.sensor_helper) probe.LookupZSteppers(config, trig_analog.get_dispatch().add_stepper) # Basic probe requests - self.probe_offsets = probe.ProbeOffsetsHelper(config) + self.probe_offsets = EddyProbeOffsets(config) self.param_helper = probe.ProbeParameterHelper(config) self.eddy_descend = EddyDescend( config, self.sensor_helper, self.calibration, self.probe_offsets, diff --git a/test/klippy/eddy.cfg b/test/klippy/eddy.cfg index 6f26899ef..fd6a2a005 100644 --- a/test/klippy/eddy.cfg +++ b/test/klippy/eddy.cfg @@ -57,7 +57,7 @@ min_temp: 0 max_temp: 130 [probe_eddy_current eddy] -z_offset: 0.4 +descend_z: 0.4 x_offset: -5 y_offset: -4 sensor_type: ldc1612