It's apparently completely broken and the fact that no one noticed
and reported that means it never really gets used either from the looks
of it.
So instead of allowing it to introduce broken resend handling, we'll
rather remove it for now.
If the printer supports the busy protocol (which we should automatically
notice by it using it on the first blocking heatup or otherwise blocking
operation), it's safe reduce the communication timeout to a way way
lower value since the busy protocol should guarantee a heartbeat from
the printer at known intervals and so timeouts really should only happen
if something gets lost on the way.
We also set the interval on the printer to our configured busy timeout
minus 1s so we can be sure that we should always see a busy line from
the printer before we run into our own timeout. We do this via M113.
* we now don't send the triggered resend/comm errors out of band but
instead as a response to the next received actual line - that
prevents us from getting out of sync
* new trigger_missing_lineno debug function to trigger a missing line
number error _without_ a resend request for testing fix for #2226
Now also detects capabilities reported by (extended) M115 output and
if AUTOREPORT_TEMP is available enables it with the configured
autoreport interval and disables active polling.
Implements #1679
Might have been an external reset of the printer we didn't otherwise
detect, and unless we reset the line numbers we'll now be off and run
into resend requests.
Solves #1676
* leading and trailing null bytes will now be stripped
* while connecting, a "wait" will also trigger switch to connected
state - relevant when connecting without reset and initial "ok" for
M110 gets mangled
* extended virtual printer by new options to test the above:
* mangled "ok" can now be injected via "preparedOks" setting and
prepare_ok DEBUG command
* simulated reset lines on beginning ("start" etc) now only sent
if new setting "simulateReset" is true
Should fix#1770
Support multi-extruder setups that share a single nozzle and heater,
like the E3D Cyclops, Diamon hotend or probably the upcoming Prusa Mk2
multi-extruder upgrade.
The Control tab will still allow tool switching and extruding for
the configured extruders, the Temperature tab will only display
one hotend temperature though.
Printer profiles have been extended by a new option
extruder.sharedNozzle that defaults to False. Extruder offsets are
not displayed in the profile editor if that setting is checked and
reset to (0,0).
Long lines (longer than rx buffer) could not be processed at all, leading
to a serial timeout exception thrown by the virtual printer. Adjusted
to allow for partial processing like on maintenance