May act as entry point for any kind of push messages a plugin might
wish to send to the client after a connect happened. Since depending
on the current permission configuration this might only be possible
once the client has authenticated on the socket, this is required.
Should close#3400
On the push socket only available for admin users.
ClientOpened now also get the remoteAddress stripped from the payload
for guests on the push socket.
Implements #783
events > subscriptions[] > event may be either a string (existing
functionality) or now a list of strings. If a list, the subscriptions
are treated the same for each event in the list.
To make it possible for command subscriptions to determine which event
was triggered, a {__eventname} substitution has been added.
It was causing a ton of issues with backend code using `Settings.save`
to persist changes outside of REST API calls, triggering configuration
update dialogs in the frontend way too often and when not needed.
Added a flag instead to cause the `save` method to trigger an event and
setting that to False by default. Settings REST API uses it, other
callees in e.g. plugin code will be able to as well in the future if
necessary.
It would be cleaner to always trigger this event and adjust calling code
and frontend code to compensate, but with third party plugins out there
this is not going to happen reliably so we go this route.
Chamber temperatures reported via M105 will only be parsed if the
fw reports chamber capabilities (through Cap:CHAMBER_TEMPERATURE:1) or
the currently selected printer profile has a heated chamber configured.
This is to avoid incompatibility issues with firmware variants that
might already use the C parameter for something else (which might be the
case since we don't have a reliable well defined standard that people
need to adhere to...)
Chamber temperature commands M141 and M191 will only be allowed to be
sent if the selected printer profile has a heated chamber configured.
This mirrors the behaviour for the bed temperature commands M140 and
M190 and heated bed configuration.
Display of chamber data in the graph will only happen if the printer
profile has a heated chamber configured.
Implements one workflow behind #321
Instead of a boolean option to block sending of M0 *and* M1 and
hardcoding them and M25 to pause an ongoing print, we now have two lists
for blocked commands and pausing commands respectively.
Blocked by default: M0 and M1.
Pausing by default: M0, M1 and M25.
Implements #2970
Adding a plugin's identifier to the list plugins._forcedCompatible in
config.yaml will make OctoPrint ignore its python compatibility status,
e.g.
plugins:
_forcedCompatible:
- myplugin
This might be helpful for plugin authors during development but should
NOT be used in production!
See also #2722