Chamber temperatures reported via M105 will only be parsed if the
fw reports chamber capabilities (through Cap:CHAMBER_TEMPERATURE:1) or
the currently selected printer profile has a heated chamber configured.
This is to avoid incompatibility issues with firmware variants that
might already use the C parameter for something else (which might be the
case since we don't have a reliable well defined standard that people
need to adhere to...)
Chamber temperature commands M141 and M191 will only be allowed to be
sent if the selected printer profile has a heated chamber configured.
This mirrors the behaviour for the bed temperature commands M140 and
M190 and heated bed configuration.
Display of chamber data in the graph will only happen if the printer
profile has a heated chamber configured.
Implements one workflow behind #321
Instead of a boolean option to block sending of M0 *and* M1 and
hardcoding them and M25 to pause an ongoing print, we now have two lists
for blocked commands and pausing commands respectively.
Blocked by default: M0 and M1.
Pausing by default: M0, M1 and M25.
Implements #2970
-4 or --ipv4 will behave as if "--host 0.0.0.0" (or any other specific
v4 address) was supplied and only bind the server socket to v4. It will
be ignored if a v6 address is set to bind to.
-6 or --ipv6 will only bind the server socket to v6 instead of dual
stack on both v4 and v6. It will be ignored if a v4 address is set to
bind to.
Implements #2904
Improves performance of file manipulation, especially in cases with a
lot of files in the folder, without the added complexity of fully
decoupling metadata file serialization from general processing.
Better fix for #3057
Makes more sense than putting them into sys.modules as <identifier>,
which also can cause conflicts (e.g. in the case of octoprint.plugins
.logging which then suddenly gets found instead of the built-in crucial
logging module).
If selected, the current layer is drawn at 30% opacity and then the progress is drawn over the top at 100%
Added additional checkbox on GCodeView page to include current layer as preview
The current 2.7 Python binary on Debian returns "2.7.15+" as its version, which
is not PEP440 compliant. Tthere is no feedback at all from Debian maintainers
regarding the bug report as of now:
https://bugs.debian.org/cgi-bin/bugreport.cgi?bug=914072
This patch makes sure to drop any trailing '+' character in a version string.
Fixes#3049
It lives on as curalegacy at
https://github.com/OctoPrint/OctoPrint-CuraLegacy
which will be added to the plugin repository once the first RC of 1.3.11
lands.
Due to this change, the general handling of STL files has also changed
slightly. They will no longer be supported by upload out of the box
unless a SlicerPlugin is available (which will now by default extend the
extension tree with STL files, unless overwritten). As a consequence of
that the file type filters in the file list have also been adjusted to
only show up if there are additional file types to filter for.