Chamber temperatures reported via M105 will only be parsed if the
fw reports chamber capabilities (through Cap:CHAMBER_TEMPERATURE:1) or
the currently selected printer profile has a heated chamber configured.
This is to avoid incompatibility issues with firmware variants that
might already use the C parameter for something else (which might be the
case since we don't have a reliable well defined standard that people
need to adhere to...)
Chamber temperature commands M141 and M191 will only be allowed to be
sent if the selected printer profile has a heated chamber configured.
This mirrors the behaviour for the bed temperature commands M140 and
M190 and heated bed configuration.
Display of chamber data in the graph will only happen if the printer
profile has a heated chamber configured.
Implements one workflow behind #321
Instead of a boolean option to block sending of M0 *and* M1 and
hardcoding them and M25 to pause an ongoing print, we now have two lists
for blocked commands and pausing commands respectively.
Blocked by default: M0 and M1.
Pausing by default: M0, M1 and M25.
Implements #2970
It lives on as curalegacy at
https://github.com/OctoPrint/OctoPrint-CuraLegacy
which will be added to the plugin repository once the first RC of 1.3.11
lands.
Due to this change, the general handling of STL files has also changed
slightly. They will no longer be supported by upload out of the box
unless a SlicerPlugin is available (which will now by default extend the
extension tree with STL files, unless overwritten). As a consequence of
that the file type filters in the file list have also been adjusted to
only show up if there are additional file types to filter for.
That will give us more accurate client ips, with a one hop limitation
however, see http://www.tornadoweb.org/en/stable/httpserver.html. If
more than one hop/reverse proxy is used in front of OctoPrint, their IPs
should be configured as server.reverseProxy.trustedDownstream in
config.yaml so they don't get detected as client IPs.
Implements #2512
* migrate several actually serial & protocol related settings from
feature settings to serial settings
* migrate terminal auto uppercase blacklist from serial settings to
feature settings
* restructure the serial settings dialog
* adjust docs accordingly
Added new config setting: auto uppercase blacklist that is configurable
in the advanced option of the serial tab, with M117 included in the
default settings of the blacklist. Changed the sendCommand method in the
TerminalViewModel to auto uppercase the entire gcode command except when
gcode is in the blacklist. Updated documentation to include the default
auto uppercase blacklist command M117.
Resolves: #1026
(cherry picked from commit dbf7af1)
RepRapFirmware enumerates the gcode files starting at /gcode, it will
also interpret any relative path as being relative to that folder.
However a full absolute path will actually interpret as from the real
root of the SD card :-(
(cherry-picked from ac68570)
"Hello" command sent to printer to trigger initial handshake can now be
configured. Commands that _always_ necessitate to be sent with checksum/
line number (e.g. M110 on Marlin) can be configured as such too.
Also fixed an issue causing the "Hello" command to not be actually enqueued
first thing on opening a connection. Seems to not have caused harm in the
wild, but was unintentional.
(cherry picked from commit 5c2ae37)
"Hello" command sent to printer to trigger initial handshake can now be
configured. Commands that _always_ necessitate to be sent with checksum/
line number (e.g. M110 on Marlin) can be configured as such too.
Also fixed an issue causing the "Hello" command to not be actually enqueued
first thing on opening a connection. Seems to not have caused harm in the