api/plugin/pluginmanager has been deprecated in favor of
plugin/pluginmanager/plugins, plugin/pluginmanager/orphans and
plugin/pluginmanager/repository. Additionally, there's now
plugin/pluginmanager/plugin/<key> to retrieve info for a specific plugin
by its identifier.
Repository and orphans are only fetched on opening of the Settings
dialog, plugins and notifications on login with required permissions.
All list endpoints make use of ETag headers.
The former simple API endpoint api/plugin/pluginmanager has been left in
the code for now but marked as deprecated. Same goes for the clientJS
API.
Implements #4035
People might not actually always have a home command in their GCODE
files, so let's just depend on the so far pretty universal truth that
printers have a bed at z=0 and that is just always the lowest Z of a
printed object. And just in case, let's make this value configurable
because the printer gods only know what some people might come up with
in terms of experimental printer mechanics that end up with negative z
coordinates or a bed at z=100.
Closes#4036
Added an ES6 polyfill, fixed some minor issues in less.js, put less.js
into lib bundle again.
Further steps should be taken to ensure the core JS files stay ES5
compliant with regards to the use of arrow functions, let, const and so
on, at least the versions bundled into the webassets.
Closes#3920
Just in case some firmware variant decides to go for case sensitivity
here (shouldn't usually happen since this should always be 8.3 names,
but people tinker...) we treat the SD file names case sensitively again.
Closes#3994
We were trying to fetch the repo url from the settings. However, due to
the settings overlays from other plugins not being available when
operating in a CLI environment, the repository URL was unset and thus
nothing was fetched.
This is now fixed by falling back to the default repo URL from the
pluginmanager, which has been extracted into a constant for that reason.
Fixes#3883
Non-ASCII host names under Windows are bad news for firing up an
HTTPServer instance. We can't fix that, but we can display a better
error message.
See https://bugs.python.org/issue26227Closes#3963
The switch back was enqueued in a timeout, however that timeout was only
ever cleared if fancy functionality was already enabled when trying to
switch it back on due to a logic error. Now it gets cleared whenever the
time needed for processing the log lines is above the threshold.
Potentially fixes#3905
409 returns on this endpoint are common if the printer is not currently
connected. Reduce log spam by rewriting such requests to INFO level,
which by default won't get logged.