✨ Support for heated chamber fw capabilities

Chamber temperatures reported via M105 will only be parsed if the
fw reports chamber capabilities (through Cap:CHAMBER_TEMPERATURE:1) or
the currently selected printer profile has a heated chamber configured.
This is to avoid incompatibility issues with firmware variants that
might already use the C parameter for something else (which might be the
case since we don't have a reliable well defined standard that people
need to adhere to...)

Chamber temperature commands M141 and M191 will only be allowed to be
sent if the selected printer profile has a heated chamber configured.
This mirrors the behaviour for the bed temperature commands M140 and
M190 and heated bed configuration.

Display of chamber data in the graph will only happen if the printer
profile has a heated chamber configured.

Implements one workflow behind #321
This commit is contained in:
Gina Häußge committed 2019-03-18 16:51:12 +01:00
1 parent b2637eb06a
commit 8d3befb01f
17 files changed
+580 -32

No files matched your search

+156 -3
View File
@@ -22,6 +22,11 @@ Bed
corresponding resource returns temperature information including an optional history. Note that Bed commands
are only available if the currently selected printer profile has a heated bed.
See :ref:`sec-api-printer-bedcommand`.
Chamber
Chamber commands allow setting the temperature and temperature offset for the printer's heated chamber. Querying
the corresponding resource returns temperature information including an option history. Note that Chamber commands
are only available if the currently selected printer profile has a heated chamber.
See :ref:`sec-api-printer-chambercommand`.
SD card
SD commands allow initialization, refresh and release of the printer's SD card (if available). Querying the
corresponding resource returns the current SD card state.
@@ -623,12 +628,12 @@ Issue a bed command
are:
target
Sets the given target temperature on the printer's tools. Additional parameters:
Sets the given target temperature on the printer's bed. Additional parameters:
* ``target``: Target temperature to set.
offset
Sets the given temperature offset on the printer's tools. Additional parameters:
Sets the given temperature offset on the printer's bed. Additional parameters:
* ``offset``: Offset to set.
@@ -710,7 +715,7 @@ Retrieve the current bed state
an :http:statuscode:`409`.
.. note::
If you want both tool and bed temperature information at the same time, take a look at
If you want tool, bed and chamber temperature information at the same time, take a look at
:ref:`Retrieve the current printer state <sec-api-printer-state>`.
**Example**
@@ -760,6 +765,154 @@ Retrieve the current bed state
:statuscode 409: If the printer is not operational or the selected printer profile
does not have a heated bed.
.. _sec-api-printer-chambercommand:
Issue a chamber command
=======================
.. http:post:: /api/printer/bed
Chamber commands allow setting the temperature and temperature offsets for the printer's heated chamber. Available commands
are:
target
Sets the given target temperature on the printer's chamber. Additional parameters:
* ``target``: Target temperature to set.
offset
Sets the given temperature offset on the printer's chamber. Additional parameters:
* ``offset``: Offset to set.
All of these commands may only be sent if the printer is currently operational. Otherwise a :http:statuscode:`409`
is returned.
Upon success, a status code of :http:statuscode:`204` and an empty body is returned.
If no heated chambed is configured for the currently selected printer profile, the resource will return
an :http:statuscode:`409`.
Requires user rights.
**Example Target Temperature Request**
Set the target temperature for the printer's heated chamber to 50°C.
.. sourcecode:: http
POST /api/printer/chamber HTTP/1.1
Host: example.com
Content-Type: application/json
X-Api-Key: abcdef...
{
"command": "target",
"target": 50
}
.. sourcecode:: http
HTTP/1.1 204 No Content
**Example Offset Temperature Request**
Set the temperature offset for the heated chamber to -5°C.
.. sourcecode:: http
POST /api/printer/chamber HTTP/1.1
Host: example.com
Content-Type: application/json
X-Api-Key: abcdef...
{
"command": "offset",
"offset": -5
}
.. sourcecode:: http
HTTP/1.1 204 No Content
:json string command: The command to issue, either ``target`` or ``offset``.
:json object target: ``target`` command: The target temperature to set.
:json object offset: ``offset`` command: The offset temperature to set.
:statuscode 204: No error
:statuscode 400: If ``target`` or ``offset`` is not a valid number or outside of the supported range, or if the
request is otherwise invalid.
:statuscode 409: If the printer is not operational or the selected printer profile
does not have a heated chamber.
.. _sec-api-printer-chamberstate:
Retrieve the current chamber state
==================================
.. http:get:: /api/printer/chamber
Retrieves the current temperature data (actual, target and offset) plus optionally a (limited) history (actual, target,
timestamp) for the printer's heated chamber.
It's also possible to retrieve the temperature history by supplying the ``history`` query parameter set to ``true``. The
amount of returned history data points can be limited using the ``limit`` query parameter.
Returns a :http:statuscode:`200` with a Temperature Response in the body upon success.
If no heated chamber is configured for the currently selected printer profile, the resource will return
an :http:statuscode:`409`.
.. note::
If you want tool, bed and chamber temperature information at the same time, take a look at
:ref:`Retrieve the current printer state <sec-api-printer-state>`.
**Example**
Query the chamber temperature data and also include the temperature history but limit it to two entries.
.. sourcecode:: http
GET /api/printer/chamber?history=true&limit=2 HTTP/1.1
Host: example.com
X-Api-Key: abcdef...
.. sourcecode:: http
HTTP/1.1 200 OK
Content-Type: application/json
{
"chamber": {
"actual": 50.221,
"target": 70.0,
"offset": 5
},
"history": [
{
"time": 1395651928,
"chamber": {
"actual": 50.221,
"target": 70.0
}
},
{
"time": 1395651926,
"chamber": {
"actual": 49.1123,
"target": 70.0
}
}
]
}
:query history: If set to ``true`` (or: ``yes``, ``y``, ``1``), history information will be included in the response
too. If no ``limit`` parameter is given, all available temperature history data will be returned.
:query limit: If set to an integer (``n``), only the last ``n`` data points from the printer's temperature history
will be returned. Will be ignored if ``history`` is not enabled.
:statuscode 200: No error
:statuscode 409: If the printer is not operational or the selected printer profile
does not have a heated chamber.
.. _sec-api-printer-sdcommand:
Issue an SD command
+9
View File
@@ -52,6 +52,7 @@ Retrieve all printer profiles
"height": 200
},
"heatedBed": true,
"heatedChamber": false,
"axes": {
"x": {
"speed": 6000,
@@ -93,6 +94,7 @@ Retrieve all printer profiles
"height": 200
},
"heatedBed": true,
"heatedChamber": true,
"axes": {
"x": {
"speed": 6000,
@@ -184,6 +186,7 @@ Add a new printer profile
"height": 200
},
"heatedBed": true,
"heatedChamber": false,
"axes": {
"x": {
"speed": 6000,
@@ -267,6 +270,7 @@ Add a new printer profile
"height": 300
},
"heatedBed": false,
"heatedChamber": false,
"axes": {
"x": {
"speed": 6000,
@@ -352,6 +356,7 @@ Update an existing printer profile
"height": 200
},
"heatedBed": true,
"heatedChamber": false,
"axes": {
"x": {
"speed": 6000,
@@ -578,6 +583,10 @@ Profile
- 0..1
- ``boolean``
- Whether the printer has a heated bed (``true``) or not (``false``)
* - ``heatedChamber``
- 0..1
- ``boolean``
- Whether the printer has a heated chamber (``true``) or not (``false``)
* - ``axes``
- 0..1
- Object