From 7d3d3408ebef48e9af8e2b09f0ba5682d8854972 Mon Sep 17 00:00:00 2001 From: =?UTF-8?q?Gina=20H=C3=A4u=C3=9Fge?= Date: Wed, 14 Feb 2018 16:52:00 +0100 Subject: [PATCH] Switch to lower comm timeouts on busy protocol detection If the printer supports the busy protocol (which we should automatically notice by it using it on the first blocking heatup or otherwise blocking operation), it's safe reduce the communication timeout to a way way lower value since the busy protocol should guarantee a heartbeat from the printer at known intervals and so timeouts really should only happen if something gets lost on the way. We also set the interval on the printer to our configured busy timeout minus 1s so we can be sure that we should always see a busy line from the printer before we run into our own timeout. We do this via M113. --- .../plugins/virtual_printer/virtual.py | 33 ++++++++---- src/octoprint/server/api/settings.py | 2 + src/octoprint/settings.py | 2 + .../static/js/app/viewmodels/settings.js | 1 + .../dialogs/settings/serialconnection.jinja2 | 8 +++ src/octoprint/util/comm.py | 50 +++++++++++++++---- 6 files changed, 77 insertions(+), 19 deletions(-) diff --git a/src/octoprint/plugins/virtual_printer/virtual.py b/src/octoprint/plugins/virtual_printer/virtual.py index a0d490fc3..5866f1b15 100644 --- a/src/octoprint/plugins/virtual_printer/virtual.py +++ b/src/octoprint/plugins/virtual_printer/virtual.py @@ -114,6 +114,7 @@ class VirtualPrinter(object): self._sendWait = settings().getBoolean(["devel", "virtualPrinter", "sendWait"]) self._sendBusy = settings().getBoolean(["devel", "virtualPrinter", "sendBusy"]) self._waitInterval = settings().getFloat(["devel", "virtualPrinter", "waitInterval"]) + self._busyInterval = settings().getFloat(["devel", "virtualPrinter", "busyInterval"]) self._echoOnM117 = settings().getBoolean(["devel", "virtualPrinter", "echoOnM117"]) @@ -427,6 +428,11 @@ class VirtualPrinter(object): filename = data.split(None, 1)[1].strip() self._deleteSdFile(filename) + def _gcode_M113(self, data): + interval = int(re.search("S([0-9]+)", data).group(1)) + if 0 <= interval <= 60: + self._busyInterval = interval + def _gcode_M114(self, data): if settings().getBoolean(["devel", "virtualPrinter", "reprapfwM114"]): output = "X:{} Y:{} Z:{} {}".format(self._lastX, @@ -536,10 +542,10 @@ class VirtualPrinter(object): elif matchS: _timeout = float(matchS.group(1)) - if self._sendBusy: + if self._sendBusy and self._busyInterval > 0: until = time.time() + _timeout while time.time() < until: - time.sleep(1.0) + time.sleep(self._busyInterval) self._send("busy:processing") else: time.sleep(_timeout) @@ -1035,19 +1041,26 @@ class VirtualPrinter(object): def _waitForHeatup(self, heater, only_wait_if_higher): delta = 1 delay = 1 + last_busy = time.time() try: if heater.startswith("tool"): toolNum = int(heater[len("tool"):]) - while not self._killed and (self.temp[toolNum] < self.targetTemp[toolNum] - delta or (not only_wait_if_higher and self.temp[toolNum] > self.targetTemp[toolNum] + delta)): - self._simulateTemps(delta=delta) - self._output("T:%0.2f" % self.temp[toolNum]) - time.sleep(delay) + test = lambda: self.temp[toolNum] < self.targetTemp[toolNum] - delta or (not only_wait_if_higher and self.temp[toolNum] > self.targetTemp[toolNum] + delta) + output = lambda: "T:%0.2f" % self.temp[toolNum] elif heater == "bed": - while not self._killed and (self.bedTemp < self.bedTargetTemp - delta or (not only_wait_if_higher and self.bedTemp > self.bedTargetTemp + delta)): - self._simulateTemps(delta=delta) - self._output("B:%0.2f" % self.bedTemp) - time.sleep(delay) + test = lambda: self.bedTemp < self.bedTargetTemp - delta or (not only_wait_if_higher and self.bedTemp > self.bedTargetTemp + delta) + output = lambda: "B:%0.2f" % self.bedTemp + else: + return + + while not self._killed and test(): + self._simulateTemps(delta=delta) + self._output(output()) + if self._sendBusy and time.time() - last_busy >= self._busyInterval: + self._output("echo:busy: processing") + last_busy = time.time() + time.sleep(delay) except AttributeError: if self.outgoing is not None: raise diff --git a/src/octoprint/server/api/settings.py b/src/octoprint/server/api/settings.py index 59115ffd3..8e74e22c7 100644 --- a/src/octoprint/server/api/settings.py +++ b/src/octoprint/server/api/settings.py @@ -142,6 +142,7 @@ def getSettings(): "timeoutConnection": s.getFloat(["serial", "timeout", "connection"]), "timeoutDetection": s.getFloat(["serial", "timeout", "detection"]), "timeoutCommunication": s.getFloat(["serial", "timeout", "communication"]), + "timeoutCommunicationBusy": s.getFloat(["serial", "timeout", "communicationBusy"]), "timeoutTemperature": s.getFloat(["serial", "timeout", "temperature"]), "timeoutTemperatureTargetSet": s.getFloat(["serial", "timeout", "temperatureTargetSet"]), "timeoutTemperatureAutoreport": s.getFloat(["serial", "timeout", "temperatureAutoreport"]), @@ -368,6 +369,7 @@ def _saveSettings(data): if "timeoutConnection" in data["serial"]: s.setFloat(["serial", "timeout", "connection"], data["serial"]["timeoutConnection"]) if "timeoutDetection" in data["serial"]: s.setFloat(["serial", "timeout", "detection"], data["serial"]["timeoutDetection"]) if "timeoutCommunication" in data["serial"]: s.setFloat(["serial", "timeout", "communication"], data["serial"]["timeoutCommunication"]) + if "timeoutCommunicationBusy" in data["serial"]: s.setFloat(["serial", "timeout", "communicationBusy"], data["serial"]["timeoutCommunicationBusy"]) if "timeoutTemperature" in data["serial"]: s.setFloat(["serial", "timeout", "temperature"], data["serial"]["timeoutTemperature"]) if "timeoutTemperatureTargetSet" in data["serial"]: s.setFloat(["serial", "timeout", "temperatureTargetSet"], data["serial"]["timeoutTemperatureTargetSet"]) if "timeoutTemperatureAutoreport" in data["serial"]: s.setFloat(["serial", "timeout", "temperatureAutoreport"], data["serial"]["timeoutTemperatureAutoreport"]) diff --git a/src/octoprint/settings.py b/src/octoprint/settings.py index 809e2d1c0..b35db756f 100644 --- a/src/octoprint/settings.py +++ b/src/octoprint/settings.py @@ -94,6 +94,7 @@ default_settings = { "detection": 0.5, "connection": 10, "communication": 30, + "communicationBusy": 3, "temperature": 5, "temperatureTargetSet": 2, "temperatureAutoreport": 2, @@ -383,6 +384,7 @@ default_settings = { "firmwareName": "Virtual Marlin 1.0", "sharedNozzle": False, "sendBusy": False, + "busyInterval": 2.0, "simulateReset": True, "resetLines": ['start', 'Marlin: Virtual Marlin!', '\x80', 'SD card ok'], "preparedOks": [], diff --git a/src/octoprint/static/js/app/viewmodels/settings.js b/src/octoprint/static/js/app/viewmodels/settings.js index 5bf115853..d6d6fb73d 100644 --- a/src/octoprint/static/js/app/viewmodels/settings.js +++ b/src/octoprint/static/js/app/viewmodels/settings.js @@ -160,6 +160,7 @@ $(function() { self.serial_timeoutConnection = ko.observable(undefined); self.serial_timeoutDetection = ko.observable(undefined); self.serial_timeoutCommunication = ko.observable(undefined); + self.serial_timeoutCommunicationBusy = ko.observable(undefined); self.serial_timeoutTemperature = ko.observable(undefined); self.serial_timeoutTemperatureTargetSet = ko.observable(undefined); self.serial_timeoutTemperatureAutoreport = ko.observable(undefined); diff --git a/src/octoprint/templates/dialogs/settings/serialconnection.jinja2 b/src/octoprint/templates/dialogs/settings/serialconnection.jinja2 index c2b57a45f..c7d0f12e3 100644 --- a/src/octoprint/templates/dialogs/settings/serialconnection.jinja2 +++ b/src/octoprint/templates/dialogs/settings/serialconnection.jinja2 @@ -61,6 +61,14 @@ s + {{ _('busy protocol support not detected')}} + +
+
+ + s +
+ {{ _('busy protocol support detected')}}
diff --git a/src/octoprint/util/comm.py b/src/octoprint/util/comm.py index 6e86c4b0f..de2afab6f 100644 --- a/src/octoprint/util/comm.py +++ b/src/octoprint/util/comm.py @@ -420,6 +420,7 @@ class MachineCom(object): self._firmware_capabilities = dict() self._temperature_autoreporting = False + self._busy_protocol_detected = False self._supportResendsWithoutOk = settings().getBoolean(["serial", "supportResendsWithoutOk"]) @@ -1229,7 +1230,7 @@ class MachineCom(object): self._changeState(self.STATE_CONNECTING) #Start monitoring the serial port. - self._timeout = get_new_timeout("communication", self._timeout_intervals) + self._timeout = get_new_timeout("communicationBusy" if self._busy_protocol_detected else "communication", self._timeout_intervals) startSeen = False supportRepetierTargetTemp = settings().getBoolean(["feature", "repetierTargetTemp"]) @@ -1250,13 +1251,33 @@ class MachineCom(object): break if line.strip() is not "": self._consecutive_timeouts = 0 - self._timeout = get_new_timeout("communication", self._timeout_intervals) + self._timeout = get_new_timeout("communicationBusy" if self._busy_protocol_detected else "communication", self._timeout_intervals) if self._dwelling_until and now > self._dwelling_until: self._dwelling_until = False + ##~~ busy protocol handling + if line.startswith("echo:busy:") or line.startswith("busy:"): + # make sure the printer sends busy in a small enough interval to match our timeout + if not self._busy_protocol_detected: + self._log("Printer seems to support the busy protocol, adjusting timeouts and setting busy " + "interval accordingly") + self._busy_protocol_detected = True + + new_communication_timeout = self._timeout_intervals.get("communicationBusy", 2) + self._serial.timeout = new_communication_timeout + busy_interval = max(int(new_communication_timeout) - 1, 1) + + self._logger.info("Printer seems to support the busy protocol, telling it to set the busy " + "interval to our \"communicationBusy\" timeout - 1s = {}s".format(busy_interval)) + + self._set_busy_protocol_interval(interval=busy_interval) + + if self._state not in (self.STATE_CONNECTING, self.STATE_DETECT_BAUDRATE): + continue + ##~~ debugging output handling - if line.startswith("//"): + elif line.startswith("//"): debugging_output = line[2:].strip() if debugging_output.startswith("action:"): action_command = debugging_output[len("action:"):].strip() @@ -1277,7 +1298,8 @@ class MachineCom(object): except: self._logger.exception("Error while calling hook {} with action command {}".format(self._printer_action_hooks[hook], action_command)) continue - else: + + if self._state not in (self.STATE_CONNECTING, self.STATE_DETECT_BAUDRATE): continue def convert_line(line): @@ -1488,7 +1510,7 @@ class MachineCom(object): if capability == self.CAPABILITY_AUTOREPORT_TEMP and enabled: self._logger.info("Firmware states that it supports temperature autoreporting") - self._set_autoreport_temperature() + self._set_autoreport_temperature_interval() ##~~ SD Card handling elif 'SD init fail' in line or 'volume.init failed' in line or 'openRoot failed' in line: @@ -1594,7 +1616,7 @@ class MachineCom(object): self._serial.timeout = connection_timeout self._log("Trying baudrate: %d" % (baudrate)) self._baudrateDetectRetry = 5 - self._timeout = get_new_timeout("communication", self._timeout_intervals) + self._timeout = get_new_timeout("communicationBusy" if self._busy_protocol_detected else "communication", self._timeout_intervals) self._serial.write('\n') self.sayHello() except: @@ -1830,7 +1852,7 @@ class MachineCom(object): if self.isOperational() and not self._connection_closing and self.isSdPrinting() and not self._long_running_command and not self._dwelling_until and not self._heating: self.sendCommand("M27", cmd_type="sd_status_poll") - def _set_autoreport_temperature(self, interval=None): + def _set_autoreport_temperature_interval(self, interval=None): if interval is None: try: interval = int(self._timeout_intervals.get("temperatureAutoreport", 2)) @@ -1838,6 +1860,14 @@ class MachineCom(object): interval = 2 self.sendCommand("M155 S{}".format(interval)) + def _set_busy_protocol_interval(self, interval=None): + if interval is None: + try: + interval = max(int(self._timeout_intervals.get("communicationBusy", 3)) - 1, 1) + except: + interval = 2 + self.sendCommand("M113 S{}".format(interval)) + def _onConnected(self): self._serial.timeout = settings().getFloat(["serial", "timeout", "communication"]) self._temperature_timer = RepeatedTimer(self._getTemperatureTimerInterval, self._poll_temperature, run_first=True) @@ -1862,7 +1892,9 @@ class MachineCom(object): self.resetLineNumbers() if self._temperature_autoreporting: - self._set_autoreport_temperature() + self._set_autoreport_temperature_interval() + if self._busy_protocol_detected: + self._set_busy_protocol_interval() def _getTemperatureTimerInterval(self): busy_default = 4.0 @@ -2803,7 +2835,7 @@ class MachineCom(object): elif s_match: _timeout = float(s_match.group("value")) - self._timeout = get_new_timeout("communication", self._timeout_intervals) + _timeout + self._timeout = get_new_timeout("communicationBusy" if self._busy_protocol_detected else "communication", self._timeout_intervals) + _timeout self._dwelling_until = time.time() + _timeout ##~~ command phase handlers